4-24 Programmer’s Manual
MSI
Description
Sets the scanner configuration values for MSI bar code.
Syntax
Enable;
FixedLength;
Length1;
Length2;
Use2CDs;
XmitCD;
UseMod10Mod11CDAlg;
Instantiate Class
classid=clsid:
795F5CAE-189C-40F6-AF41-3604B108FF6A>
Field Description
Enable
Enables/disables the ability to scan MSI bar codes.
Default: false
FixedLength
If FixedLength is true, lengths 1 and 2 are fixed; if
FixedLength is false, length 1 is the minimum and
length 2 is the maximum. Default: false
Length1
Length2
Specifies lengths (including start and stop
characters) for MSI bar codes.
Length 1: 0, 1-99, Default: 6
Length 2: 0, 1-99, Default: 55
Use2CDs
Indicates the bar code contains two check digits
instead of one. If true, enable
UseMod10Mod11CDAlg. Default: false
XmitCD
Enables/disables the requirement to transmit data
with the check digit. Default: false
UseMod10Mod11CDAlg Uses the Mod10/Mod11 check digit algorithm instead
of Mod10/Mod10 algorithm.
Default: false