4-22 Programmer’s Manual
I2of5
Description
Sets the scanner configuration values for I2of5 bar code.
Syntax
Enable;
FixedLength;
Length1;
Length2;
VerifyCD;
XmitCD;
XlateToEAN13;
Instantiate Class
classid=clsid:
370F6557-9281-4EAD-9F2A-3DBF260BD501>
Field Description
Enable
Enables/disables the ability to scan I2of5 bar codes.
Default: true
FixedLength
If FixedLength is true, lengths 1 and 2 are fixed; if
FixedLength is false, length 1 is the minimum and
length 2 is the maximum. Default: true
Length1
Length2
Specifies lengths (including start and stop characters)
for I2of5 bar codes.
Length 1: 0, 2-99, Default: 14
Length 2: 0, 2-99, Default: 0
VerifyCD
Specifies whether the scanner should check the
integrity of 2of5 bar codes to ensure they comply with
either the Uniform Symbology Specification (USS) or
Optical Product Code Council (OPCC) algorithms.
Default: false
XmitCD
Enables/disables the requirement to transmit check
digits with the data. Default: false