Masonry chimney conversions, Installation addenda, Addendum #2 interior masonry chimney conversions – Avalon Firestyles Salish-1999 to 2000 User Manual
Page 35

Installation Addenda
35
Travis Industries
9 3 5 0 8 1 0 7
1 0 0 2 0 1
ADDENDUM #2 Interior Masonry Chimney Conversions
¥
Follow the requirements and use the equipment listed in the illustration to the right to install this
appliance into an interior masonry chimney.
¥
Maximum vertical rise is 30'
¥
Minimum vertical rise is 10'
¥
Use the following restrictor positions:
Position 2 for heights between 8Õ and 12Õ
Position 3 for heights between 12Õ and 35'
NOTE: these restrictor positions are based upon lab tests. The ideal restrictor position may vary
slightly.
The entire chimney system
must be air-tight. Make sure to
seal the flashing, clean-out,
and thimble connection, and to
inspect the chimney.
#711 Flex Liner
(4Ó dia.)
(or other UL 1777
Gas Liner)
Co-Axial
Straight
Lengths
#991 High
Wind
Termination
#990 90¡ Elbow
Flashing
(included in
#934 Masonry
Conversion Kit
Make sure the coaxial pipe
maintains a 1Ó clearance to any
combustible. The vent must be
sealed air-tight.
High-Temp.
Silicone
Connector with
Cover (included
in #934
Masonry
Conversion Kit