beautypg.com

Installation addenda, Chimney conversion, Addendum #1 class a chimney conversion kit – Avalon Firestyles Salish-1999 to 2000 User Manual

Page 34

background image

34

Installation Addenda

Travis Industries

9 3 5 0 8 1 0 7

1 0 0 2 0 1

ADDENDUM #1 Class A Chimney Conversion Kit

Simpson Duravent provides a conversion kit for those wishing to use an existing wood stove chimney to vent
this direct vent stove. The illustration below gives an overview of this type of installation. See the instructions
included with the kit for details.

!

The conversion kit does not work on interior masonry chimneys.

!

Do not exceed the maximum vertical rise (see the section "Approved Vent Configurations" starting on page 9)
allowable. Remember to set the restrictor position to the correct position (based upon the vertical rise height -
see the chart on page 10).

Chimney Conversion Kit A (# 931)

Metalbestos 6" I.D.
Security Chimneys 6" I.D.
Jackes-Evans 6" I.D.
Hart & Cooley 6" I.D.
Pro-Jet 6" I.D.

Chimney Conversion Kit B (# 932)

Simpson Dura-Vent 6" I.D.
Air-Jet 6" I.D.
Metal-Fab 6" and 7" I.D.
Amer. Metals 6" & 7" I.D.
Metalbestos 7" and 8" I.D.
Jackes-Evans 7" and 8" I.D.
Hart & Cooley 7" and 8" I.D.
Pro-Jet 7" and 8" I.D.
Security Chimneys 8" I.D.

Chimney Conversion Kit C (# 933)

Simpson Dura-Vent 7" and 8" I.D.
American Metals 8" I.D.
Air-Jet 8" I.D.
Metal-Fab 8" I.D.
American Metals 8" I.D.

Each Kit Contains:
Retro Connector
Retro Vertical Top

Additional Required Equipment:
4" Flex (#711 or U.L. 1777)
Termination (#991)
Co-Axial Sections

Type A Chimney

Simpson Duravent Direct
Vent Pipe Sections
(use adjustable section)

Screw the Retro
Vertical Top to the
Flex Pipe

Retro Vertical Top
(screw to chimney)

Screw the Retro
Connector to the
Flex Pipe

Retro Connector
(screw to chimney)

4" (100 mm)
Aluminum Flex
Pipe

Cut the Flex Pipe to
the chimney height
plus 3" (75 mm)