Installation – Avalon Firestyles Salish-1999 to 2000 User Manual
Page 10

10
Installation
(for qualified installers only)
Travis Industries
9 3 5 0 8 1 0 7
1 0 0 2 0 1
Approved Venting Configurations for Vertical Terminations with
(or without) Two 45¡ Elbows
¥
10Õ Minimum System Height
(with or without offsets)
¥
35Õ Maximum System Height
¥
6Õ Maximum Offset
¥
The termination must fall within the shaded area
shown in the chart. Use the indicated restrictor
position.
¥
If using offsets, use the table below to calculate
the vertical rise and horizontal offset
Offset
Length
Horizontal
Offset
Vertical
Rise
Offset Length
Hor. Offset
Vert. Rise
None
5 Ó
1Õ
1Õ Section
1Õ
1Õ 7Ó
2Õ Section
1Õ 9Ó
2Õ 4Ó
3Õ Section
2Õ 5Ó
3Õ
4Õ Section
3Õ 2Ó
3Õ 8Ó
4Õ + 1Õ Section
3Õ 9Ó
4Õ 4Ó
4Õ + 2Õ Section
4Õ 6Ó
5Õ
4Õ + 3Õ Section
5Õ 2Ó
5Õ 9Ó
4Õ + 4Õ Section
6Õ
6Õ 9Ó
5 feet
10 feet
(min.)
15 feet
20 feet
25 feet
30 feet
0 feet
35' (max)
0 feet
3 feet
6' (max)
5 feet
0 feet
0 feet
Restrictor
Position # 1
The maximum
offset lengths is
two 4' sections.
NOTE:
Restrictor positions
are based upon lab
tests. The ideal
restrictor position
may vary slightly,
especially when the
termination is near
a demarkation line.
Restrictor
Position # 3
Do not place an
elbow directly off the
top of the heater.
3 feet
6' (max)
10 feet
(min.)
15 feet
20 feet
25 feet
30 feet
35' (max)