Approved Venting Configurations with a Horizontal Termination

¥

A Minimum of 2' rise is required directly off of the heater

¥

If using a Snorkel Termination (14" or 36") add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

¥

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10 feet

0 feet

11' (max)

5 feet

10 feet

0 feet

5 feet

10 feet

12'(max)

5 feet

0 feet

0 feet

NOTE:
Horizontal sections require a 1/4" rise every 12" of travel.

10 feet

11' (max)

12'(max)

NOTE:
Restrictor positions
are based upon lab
tests. The ideal
restrictor position may
vary slightly,
especially when the
termination is near a
demarkation line.

Restrictor

Position # 5

NOTE:
A minimum 2' rise is required
directly off of the stove.

Restrictor

Position # 1