- For Qualified Installers Only!

Approved Venting Configurations for
Vertical Terminations with (or without)
Two 45

°

Elbows

¥

10' Minimum System Height
(with or without offsets)

¥

33' Maximum System Height

¥

6' Maximum Offset

¥

The termination must fall within the shaded
area shown in the chart. Use the indicated
restrictor position.

¥

If using offsets, use the table below to
calculate the vertical rise and horizontal
offset

Offset
Length

Horizontal
Offset

Vertical

Rise

Offset Length

Hor. Offset

Vert. Rise

None

5"

1'

1' Section

1'

1' 7"

2' Section

1' 9"

2' 4"

3' Section

2' 5"

3'

4' Section

3' 2"

3' 8"

4' + 1' Section

3' 9"

4' 4"

4' + 2' Section

4' 6"

5'

4' + 3' Section

5' 2"

5' 9"

4' + 4' Section

6'

6' 9"

5 feet

10 feet

(min.)

15 feet

20 feet

25 feet

30 feet

0 feet

33' (max)

5 feet

0 feet

5 feet

6' (max)

5 feet

15 feet

20 feet

25 feet

30 feet

0 feet

0 feet

10 feet

(min.)

6' (max)

Restrictor

Position # 5

The maximum
offset lengths is
two 4' sections.

NOTE:
Restrictor positions
are based upon lab
tests. The ideal
restrictor position
may vary slightly,
especially when the
termination is near
a demarkation line.

Restrictor

Position # 7

28' 6"

Do not place an
offset directly off the
top of the heater.