Fireplace Placement Requirements
Minimum Framing Dimensions
The fireplace requires a 1/2" space between the fireplace and the framing members (or other
materials) along the sides and back of the fireplace. The stand-offs (and nailing brackets) may
contact the framing members but no material may be placed into the 1/2" space.
Route the electrical line to a position
to the right rear of the fireplace.
Thermostat or Remote
Control Wire (either side)
27-1/4"
Vent Clearances:
1" to the sides, 1" below, and 3" above
the vent to combustibles.
20-1/4"
34-1/4"
12-3/4"
Firestop
(required)
HINT: we recommend reinforcing the
upper corners of the fireplace opening.
4-3/4"
3-5/8"
NOTE: The rear vent may require extra
clearance - make sure to accommodate the
vent when determining the framing.
Center of Rear Vent
WARNING: A cut-out for the gas line
will be required on the framing. See
the dimensions on page 6 and "Gas
Line Connection" for details.
•
Fireplace must be installed on a level surface capable of supporting the fireplace and vent
•
Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or
carpet)
•
This heater may be placed in a bedroom. Please be aware of the large amount of heat this
appliance produces when determining a location.
Clearances
•
When installed, walls in front of the fireplace must be a minimum 1" to the side of the
faceplate.
•
Due to the high temperature, the heater should be located out of traffic and away from furniture
and draperies.
•
Fireplace must be placed so the vents below and above the glass do not become blocked