Installation (for qualified installers only), Corner installations, Raised fireplaces – Avalon Firestyles 21 DV RV User Manual
Page 11

Installation (for qualified installers only)
11
© Travis Industries
4060517
100-01158
Corner Installations
A typical 45° installation
uses the framing
dimensions shown in the
illustration to the right
(NOTE: all clearances still
apply).
NOTE: When using a 45°
elbow and venting directly
to the rear, use the
venting configuration
outlined in "Horizontal
Termination with 45°
Elbow - (NG or LP)" on
page 21.
The recommended
dimensions shown to the
right allow additional
space, easing gas line
and electrical
connections.
1/2" Nailing Brackets
6" Typical
6-1/2" Recommended
37" Min.
37-1/2" Recommended
Minimum 1" Clearance
NOTE: Max,
12"
Section.
Raised Fireplaces
NOTE: Looking Glass and
Wilmington Faces
require a raised
fireplace - see
"Dimensions" for
details.
•
The fireplace (and hearth,
if desired) may be placed
on a platform designed to
support the fireplace (125
Lbs.) and vent.
•
The fireplace may not be
raised so as to place the
ceiling in front of the
fireplace within 57" of the
base of the fireplace.
Raised
Platform
Optional Hearth
Minimum 57"
Fireplace Enclosure
(min. 34-1/4")
Ceiling