Installation (for qualified installers only)

© Travis Industries

4060517

100-01158

Electrical Line Connection

a

b

Insert the sheathed cable from the power source through

this cable clamp. Once the wires are attached, tighten

the clamp to secure the cable.

Replace the

cover removed

in step "a".

Attach the common (white), ground (exposed or green)

wires, and hot (black) wires from the power source to the

electrical connector (attached to the fireplace).

c

d

Standard
Screwdriver

Remove the cover

from the fireplace

junction box.

1/4" Nutdriver

WARNING: Make sure power is

off from the power lead before

conducting any wiring.

Electrical

Connector

Optional Electrical Line Location

c

Remove the eight screws securing the

access plate and electrical inlet

assembly (save these screws).

a

1/4" Nutdriver

b

Remove the cover plate on the bottom

of the fireplace (save the nuts).

Position the electrical inlet assembly over the hole in

the baseplate of the fireplace and secure using the

screws removed in step “a”.

1/4" Nutdriver

d

5/16" Wrench

Attach the cover plate to the access plate using

the two nuts removed in step “b”. Attach the

access plate to the fireplace using the screws

removed in step “a”.

1/4" Nutdriver

Electrical Inlet

Assembly

Access Plate

5/16" Wrench

Cover Plate