beautypg.com

Installation (for qualified installers only), Facing detail –facing over 1” thick (brick) – Avalon Firestyles 21 DV RV User Manual

Page 28

background image

28

Installation (for qualified installers only)

© Travis Industries

4060517

100-01158

Facing Detail –Facing Over 1” Thick (Brick)

WARNING:

Any facing that extends in front of the faceplate on the sides or top must be non-
combustible.

NOTE:

A 3/8” gap is required above the face for face installation.

Top View

NOTE: Make sure to leave a 1/8" gap
around the sides of the face and 3/8"
above (for face installation).

Fireplace

Face

Drywall

Framing

Non-combustible facing material (brick, stone,
marble, tile) - required if the facing extends in
front of the face on the sides or top.

3/8"

The facing is brought up
to the wall trim.

The side facing should be spaced 1/8"
from the face (3/8” from the stand-offs).

Wall Trim

Side View

Fireplace

NOTE: Make sure to bring the facing up
to the wall trim.

In this example brick is used.

1/8"

3-d View

1/4" Nutdriver

Arched Face Thick Facing Template Part #

225-20040

The Arched Face Thick Facing Template is a
separate component that is required when
using an arched face with facing that extends
beyond the face (e.g.: brick, river rock). It
attaches to the top stand-off with the included
screws. The top edge of the template forms an
arch 3/8” above the face, allowing installers to
use it as a guide for facing installation. Leave
the template in place to hide the construction
materials behind the template.

Arched Face Thick

Facing Template

NOTE: When installed, there must be a minimum 1/8” gap
between the face and facing.