42 installation, For qualified installers only) – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual
Page 42
42 Installation
(for qualified installers only)
© Travis Industries
4140926
100-01395
Thick Facing with Fireplace Xtrordinair (FPX) Arched Faces
The following illustration shows facing considerations for those fireplaces utilizing FPX arched faces.
The facing must be non-combustible and over 1" (25mm) in depth.
The Fireplace Xtrordinair 564
Masonry Template is
recommended for masonry
installation (sku 98500674). The
template helps locate and
support the masonry as it being
installed.
Masonry Line
Hearth Line
Drywall
Floor-Mounted Fireplaces or Raised Hearths:
Build the hearth 1" max (25mm) above the base
of the fireplace. The fireplace may be raised to
accommodate thicker hearth materials.
Raised Fireplaces:
Masonry is installed 1" maximum
(25mm) above the base of the
fireplace.
FRONT VIEW
29"
737mm
1"
25mm
36-1/4"
921mm
2-3/4"
70mm
61" Radius (1549mm)
Before installing masonry, install
the FPX Face Upgrade Kit
(98500683). This covers the
upper corners.
Fireplace
Drywall
Framing
Nailing Bracket
Masonry
TOP VIEW
Face