30 installation, Ng applications lp applications, For qualified installers only) – Avalon Firestyles 564 Diamond-Fyre GSR2 Installation User Manual
Page 30

30 Installation
(for qualified installers only)
© Travis Industries
4140926
100-01395
Rear Vent Configuration with Horizontal Termination (no vertical rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and
diffuser positions.
Optional 45 Degree Elbow
Termination
See the charts below to
determine maximum vent
3 feet
915mm
0 feet
mm
0 feet
mm
4' (max)
610mm
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
Vent with No 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max.48" (1.2m) Horizontal Section(s)
3 feet
915mm
0 feet
mm
0 feet
mm
2' (max)
1.2m
Vent with 1 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal Section(s)
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
NG Applications
LP Applications
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" (102mm) Horizontal Section
• Max.48" (1.2m) Horizontal Section(s)
3 feet
915mm
0 feet
mm
0 feet
mm
4' (max)
610mm
Vent with No 45° Elbow
14" Snorkel
(REQUIRED)
3 feet
915mm
0 feet
mm
0 feet
mm
2' (max)
1.2m
Vent with 1 45° Elbow
• Min. 4" (102mm) Horizontal Section
• Max. 24" (610mm) Horizontal Section(s)
• Exhaust Restrictor:
Remove the exhaust restrictor
and replace the screws.
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
14" Snorkel
(REQUIRED)