Safety notice, Stove installation, Planning the installation – Avalon Firestyles 1250 Wood Stove User Manual
Page 7: For qualified installers only), Preparation for installation, Stove installation considerations

Stove
Installation
(for qualified installers only)
7
© Travis Industries
100-01178
4081029
SAFETY NOTICE:
Please read this entire manual before you install and use your new room heater. Failure to
follow instructions may result in property damage, bodily injury, or even death. Contact
local building or fire officials about restrictions and installation inspection requirements in
your area.
Always use gloves when operating a hot stove. The door handle and other components become very
hot during normal use.
Planning The Installation
We suggest that you have an authorized Travis Industries dealer install your stove. If you install the
stove yourself, your authorized dealer should review your installation plans.
Check with local building officials for any permits required for installation of this stove and notify your
insurance company before proceeding with installation.
The location of your wood heater in your home will decide how affectively the heat produced will spread
throughout your house. Attention to the home design with consideration of natural convection and air
circulation should be taken into account when choosing the placement of your heater within the home.
Preparation for Installation
The stove can be lightened by removing the firebricks and baffle (pg. 31) - replace before operation.
Check for damage to the exterior of the stove.
Check the interior of the firebox (replace
cracked firebrick and make sure baffle is in
place).
The stove must be installed with the legs (see
page 36) or pedestal (see page 36).
Install the pipe heat shield following the
directions in Figure 2.
Stove Installation Considerations
Figure 2
The table below details the six most common types of installations and the considerations for each type.
Alternative methods of installation are available if they comply with local building codes.
Installation Type
Considerations
Standard Ceiling with a Factory Built Chimney
(Page 15)
Requires ceiling and roof penetration
Provides best draft
Cathedral Ceiling with a Factory Built Chimney
(Page 15)
Cathedral style chimney support required
Provides best draft
Hearth Stove Positive Connection
(Page 16)
Utilizes existing masonry fireplace (not approved for zero clearance
(metal) fireplaces)
Provides good draft due to full reline
Easier to clean than direct or horizontal hearth stove
Hearth Stove Direct Connection
(Page 17)
Utilizes existing masonry fireplace (not approved for zero clearance
(metal) fireplaces)
Requires construction of a "block-off plate"
Draft reduced due to elbows & chimney cross section
Interior Masonry Chimney
(Page 17)
Utilizes existing masonry chimney (not approved for zero clearance
(metal) fireplaces)
The pipe heat
shield is shipped
inside the stove.
Slide it into the
convection
chamber and
secure it with the
three screws
included in the
owner’s pack.