12 stove installation, Chimney termination requirements, Outside air requirements – Avalon Firestyles 1250 Wood Stove User Manual
Page 12

12 Stove
Installation
(for qualified installers only)
© Travis Industries
100-01178
4081029
Chimney Termination Requirements
Must have an approved cap (to prevent water from entering).
Must not be located where it will become plugged by snow or other material.
Must terminate at least 3' (914mm) above the roof and at least 2' (610mm) above any portion of the
roof within 10' (3.04M) - see Figure 7.
Figure 7
Outside Air Requirements
Required for mobile homes & in certain localities (check with building officials).
Must not be drawn from an enclosed space (garage, unventilated crawl space).
Requires the optional outside air connector or pedestal.
Air duct maximum length is 15’ (4.57M) with a minimum cross-section of 16 square inches
(10404mm) or 6’ (1.82M) with a minimum cross section of 7 square inches (4489mm).
Figure 8
Min. 3’ (914mm)
Min. 2’ (610mm)
10’ (3.04M)
Min. 3’ (914mm)
10’ (3.04M)
Min. 2’ (610mm)
Outside Air
Connector
Outside air entrance must be placed so
it does not become blocked by snow.
Pedestal or outside air boot may
be used to direct air from below
the stove. See the pedestal
instructions for complete details.
Air may be drawn from a ventilated
crawl space or use an air duct.
The pedestal has an air
opening for use with the
outside air connections.
This allows air to be
drawn from behind the
pedestal.