Listing Label
The listing label (safety label) is attached to the back of the stove. A copy is shown below.
DO NOT REMOVE THIS LABEL
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.
SUITABLE FOR USE IN CONVENTIONAL RESIDENTIAL INSTALLATIONS, MANUFACTURED HOMES AND ALCOVES.
Report No. B0527PRT-001
Control No. 4000515
MODEL:
1250
Certified for USA and Canada
SERIAL NO:
CONFORMS TO UL STD 1482; CERTIFIED TO ULC STD S627-2000
PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local
building or fire officials about restrictions and installation inspection in your area. Refer to local building codes and manufacturer’s instructions
for precautions required for passing a chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall
or ceiling. Do not connect this unit to a chimney flue serving another appliance. Clearances may be reduced by methods specified in NFPA 211,
listed wall shields, pipe shields, or other means approved by local building or fire officials.
FREESTANDING INSTALLATION
STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black, with listed UL-103 HT factory-built chimney, suitable for
use with solid fuels or masonry chimney. Pedestal or legs are required.
ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required.
MANUFACTURED HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition, manufactured
home installations require outside air - use the optional pedestal or outside air boot.
● AMERI-TEC model DCC connector with model HS chimney
● DURA-VENT model DVL connector with DURA-PLUS chimney
● GSW-JAKES EVANS SUPERPIPE 2100
● I.C.C. EXCEL (103-HT) chimney with HP connector
● METALFAB model DW connector with TG chimney
● OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney
● SECURITY model DP connector with SECURITY model ASHT or S2100 chimney
● SELKIRK METALBESTOS model DS connector with model SSII chimney
● OLYMPIA VENTIS
®
with Ventis doublewall black stove pipe
A.
B.
C.
D.
E.
F.
G.
H.
18 in. / 458 mm
18 in. / 458 mm
10 in. / 254 mm
27 in. / 689 mm
19.25 in. / 489 mm
17.75 in. / 451 mm
US: 6 in.
(153 mm) / CAN: 8 in. (204 mm)
US: 16 in.
(407 mm) / CAN: 18 in. (458 mm)
18 in. / 458 mm
10.5 in. / 267 mm
10 in. / 254 mm
26.5 in. / 674 mm
11.25 in. / 286 mm
17.25 in. / 439 mm
US: 6 in.
(153 mm) / CAN: 8 in. (204 mm)
US: 16 in.
(407 mm) / CAN: 18 in. (458 mm)
Singlewall Connector
Conventional Residential
Installations
Minimum Clearances
To Combustibles And
Hearth Requirements:
Alcove, Manufactured Home and Reduced
Clearance Conventional Residential
Installations
FREESTANDING CLEARANCE DIAGRAM
ALCOVE SPECIFICATIONS
FLOOR PROTECTION DIAGRAM
STOVE
D
A
E
B
ST
OVE
45˚
F
C
SIDEW
A
LL
BACKWALL
ADJACENT WALL
ADJACENT W
A
LL
G
STOVE
G
G
H
FRONT
FLOOR PROTECTOR
Floor protection must be a non-combustible
material extending beneath the heater and to
the front, sides and back as indicated. See
Owner’s Manual for examples of non-com-
bustible materials that can be used.
Do not obstruct space beneath heater.
Max. Alcove Depth:
Min. Alcove Height:
Min. Alcove Width:
48 in. (1220 mm)
See Owner’s Manual
See Owner’s Manual
Electrical Rating:
Optional Blower:
115V., 60 Hz, 1.8 Amps
# 99000138
Replace glass only with 5mm neoceramic or
ceramic glass.
Do not route power cord under or in front of appliance.
TRAVIS INDUSTRIES, INC.
12521 Harbour Reach Drive
Mukilteo, WA 98275
Manufactured by:
www.travisproducts.com
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020. 4.4 g/h, Method 28, 5H, 2015
Made in U.S.A.
2015