PCI

PCIScanTest (SP): Enumerates all active PCI devices in the blade and ensures board default
configuration is active. This test need to be executed under supervisory mode.

4.6.6

IPMC

IPMITest (SP): Executes basic IPMI commands and ensures the basic IPMI controller, IPMI
bus functionalities are working properly by reading the response back.

IPMCSENSOREVENTTest (SP): Verifies IPMC Event generation.

4.6.7

NETWORK

EthLinkTest (SP & PP): Verifies Ethernet device (for example: eth0, eth1, eth2, etc...) link
status (active/inactive) and also captures various statistics of Ethernet device.

FloodPingTest (SP & PP): Uses the ICMP protocol’s mandatory ECHO_REQUEST
datagram to elicit an ICMP_ECHO_RESPONSE from a host or gateway.

EthStatsTest (SP): Tests basic network packet consistency that is checks network Rx, Tx
errors, generates a warning if errors are less than or equal to 100 and marks the test as fail
if number of errors are more than 100.

NetworkCntlrTest (SP): Verifies random data transmitted and also the data received for
each configured network device. It verifies only Ethernet and token ring devices that are
configured and active. The asynchronous devices are not verified.

SfpDetectionTest(SP): Enumerates all SFP modules connected to SFP ports of blade and
their operational speeds.

SwitchTempTest (SP): Gets the temperature (in degrees Celsius and can be negative) of
the Ethernet switch. Obtained temperature value will be compared with the minimum and
maximum values of the chipset given in the specification.