Installing the ViewCheck Service OS image on SP

Before installing the ViewCheck service OS Image, you should have the knowledge of
configuring TFTP Server, configuring ATCA-9405 for Network Booting and Booting ATCA-9405
using a ramdisk. For more information, refer to the section 2.3 in Blade Services Software on
ATCA-9405 PR guide
.

1. Once the blade is configured to boot with ramdisk image, it will have ViewCheck

and Blade Services Framework installed.

2. SP should also have the interfaces to PP1 and PP2 configured so that a

communication can be established between SP and PP's.

Installing the ViewCheck Service OS image on PP

The following procedure is to boot the ViewCheck OOS image on PP. For more information,
refer to section 2.6.5 in Blade Services Software on ATCA-9405 Programmer’s Reference Guide.

1. On SP, go to /opt/diagnostics/etc/diag/ location and execute the

runlinux scripts.

For installing ViewCheck Service OS image on PP1, execute ./runlinux 1
command.

For installing ViewCheck Service OS image on PP2, execute ./runlinux 2
command.

Installing ViewCheck Service OS Image on USB

The ViewCheck service OS image can be installed on any external USB drive using flashprep
and flashinstall tools available on the board.

Use the flashrc tool available on the board to install the ViewCheck service OS image on USB
device.

Before installing ViewCheck Service OS image on PP, make sure that vlans are configured
appropriately to reach Octeons.