BSF(diag-SP_VEE0-networkinterface)#start-monitor monitorId 1020

deviceInstance 63

MONITOR IS STARTED

To exit from the ViewCheck CLI:

BSF(diag-SP_VEE0)#exit

BSF(VEE-vee0)#exit

BSF(config)#exit

#exit

4.6

Access and Execution of a Test Using XML

You can access ViewCheck XML interface similar to ViewCheck CLI.

1. Establish the secure shell using SSH or Putty.

2. Start the Telnet connection from an already established secure shell.

telnet localhost 15550

Trying 127.0.0.1...

Connected to localhost.localdomain (127.0.0.1).

Escape character is '^]'.

4.6.1

Authenticate

After a connection with the XML Agent is established, the only command which should be
executed is Authenticate. This command is for evaluating user credentials.

The Authentication command contains user name and password for verification. Successful
authentication is indicated by the success response, otherwise an error message is returned.