Installation of viewcheck – Artesyn ViewCheck on ATCA-9405 Installation and Use (May 2014) User Manual
Page 39

Installation of ViewCheck
ViewCheck on ATCA-9405 Installation and Use (6806800S51D)
39
After logging into the ViewCheck CLI, you can list all the commands supported by typing '?'
on the CLI console. For information on commands to be used to install and LOG to ViewCheck,
refer
BSF(diag-SP_VEE0)#?
configure-error-strings User configurable error strings, notified
by ViewCheck when reported by the device.
configure-log-path
Configures the log path where the resluts
are stored.
device-category Configure deviceCategory
diag-service Diag operation(start/stop/restart).
exit Exit from diagnostic
hw-inventory-list
Provides the Inventory of Hardware (Type,
Vendor ID, Major Number, Minor Number and
any associated Details) as detected by the
Diagnostics Application.
list-all-tests Displays all the supported tests on the
Board.
purge-all-log
All log files are Zipped and stored away.
purge-log Purge specific log file.
reload User can issue this command when there
are updates to the User XML.
set-log-level Sets the Log Level of Diagnostic
Application.
show-all-monitors Displays all the supported Monitors on
the Board.
show-diag-scan-result Displays the last run result of Diagscan.
show-log-content
Displays the content of log files related
to Rawlogs and ResultsLog of ViewCheck.
show-log-info List all Log files of Diagnostics
Application.
show-running-mode Displays the current running mode of
ViewCheck.
show-systemerror-log show system error log.
start-all-monitors Starts all the supported Monitors
available on the board or related to a
device category.
start-diag-scan Executes the Diagnostics tests supported
on the Board.
- ViewCheck on ATCA-F140 Installation and Use (September 2014) ViewCheck on ATCA-7370 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (November 2014) ViewCheck on ATCA-7470/7475 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (May 2014) ViewCheck on ATCA-F140 Installation and Use (November 2014) ViewCheck on ATCA-9405 Installation and Use (September 2014) ViewCheck on ATCA-7480 Installation and Use (April 2015) ViewCheck on ATCA-9405 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (May 2014) ViewCheck on ATCA-7370 Installation and Use (April 2014)