Installation of ViewCheck
ViewCheck on ATCA-9405 Installation and Use (6806800S51D)
38
4.5
Access and Execution of a Test Using CLI
You can access ViewCheck CLI using the following procedure:
1. Establish the secure shell using SSH or Putty.
2. Start the Telnet connection from an already established secure shell.
telnet localhost 11001
Trying ::1...
telnet: connect to address ::1: Connection refused
Trying 127.0.0.1...
Connected to localhost.localdomain (127.0.0.1).
Escape character is '^]'.
Welcome to Emerson's SSF CLI
3. Type your username and password.
Username: Admin
Password:
Access granted
>enable
#configure terminal
BSF(config)#
4. Select Virtual Execution Environment as below:
On SP, use the virExecEnv SP_VEE0 options in the virExecEnv
BSF(config)#virExecEnv virExecEnv SP_VEE0
BSF(VEE-SP_VEE0)#diagnostic
BSF(diag-SP_VEE0)#
On PP, use the OCTEON1_VEE0/OCTEON1_VEE1 options in the virExecEnv
BSF(config)#virExecEnv OCTEON1_VEE0
BSF(VEE-OCTEON1_VEE0)#diagnostic
BSF(diag-OCTEON1_VEE0)#
By default, the administrator user name and password are "Admin".
- ViewCheck on ATCA-F140 Installation and Use (September 2014) ViewCheck on ATCA-7370 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (November 2014) ViewCheck on ATCA-7470/7475 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (September 2014) ViewCheck on ATCA-7470/7475 Installation and Use (May 2014) ViewCheck on ATCA-F140 Installation and Use (November 2014) ViewCheck on ATCA-9405 Installation and Use (September 2014) ViewCheck on ATCA-7480 Installation and Use (April 2015) ViewCheck on ATCA-9405 Installation and Use (November 2014) ViewCheck on PrAMC-7311 Installation and Use (May 2014) ViewCheck on ATCA-7370 Installation and Use (April 2014)