Positioning the Fireplace
Determine the exact position of the appliance so the direct vent
termination will be centered (if possible) between two (2) studs.
This will avoid any extra framing. All vent kit pipes should be
assembled on the unit after the unit is moved into the final
position.

CHART 1 (Figures 20 and 21)
Venting with One (1) 90

°

Elbow or Two (2) 90

°

Elbows

Total Vertical

Total Horizontal

(With Fire Box) V

H

1

or H

1

+ H

2

4.5' minimum

3' maximum

4.5' minimum

4' maximum

5' minimum

8' maximum

6' minimum

12' maximum

7' minimum

15' maximum

8' minimum

20' maximum

25' maximum vertical
20' maximum horizontal run

Figure 21 and Chart 1 list examples of possible venting systems
using two (2) 90

°

elbows. V is listed as minimum vertical

dimensions and H1 + H2 is listed as total of maximum horizontal
dimensions. The maximum vertical and horizontal distances for
two (2) 90

°

elbows as shown in Figure 21 are 20 feet.

Attention: Refer to Figure 10 for additional venting requirements.

SEE CHART FOR PERMISSIBLE "H" AND "V" DIMENSIONS

NOTE: H1 AND H2 MUST BE ADDED TOGETHER TO USE CHART

Figure 21

INSTALLATION (continued)

12 3/8"

10 3/8"

DVS-36 44 3/4" 114cm

DVS-42 46 3/4" 118cm

CENTER OF ELBOW

STRAIGHT OUT

DVS-30 37 5/8" ( 956mm)

CENTER OF ELBOW

STRAIGHT OUT