beautypg.com

2 power requirements, Table 2-1, Environmental requirements – Artesyn RTM-ATCA-F120 Installation and Use (August 2014) User Manual

Page 29: Hardware preparation and installation

background image

Hardware Preparation and Installation

RTM-ATCA-F120-OPT Installation and Use (6806800G29D)

29

2.3.2

Power Requirements

The RTM has a typical power dissipation of 22W, and a maximum power dissipation of 30W.

Table 2-1 Environmental Requirements

Requirement

Operating

Non-Operating

Temperature

0ºC to +40ºC (normal operation) according
to NEBS Standard GR-63-CORE
0ºC to +55ºC (exceptional operation)
according to NEBS Standard GR-63-CORE

-40ºC to +85ºC

Temp. Change

+/- 0.25ºC/min according to NEBS
Standard GR-63-CORE

+/- 0.25ºC/min

Rel. Humidity

5% to 95% non-condensing according to
Artesyn-internal environmental
requirements

5% to 95% non-condensing
according to Artesyn-internal
environmental requirements

Vibration

0.1g from 5 to 100 Hz and back to 5 Hz at
a rate of 0.1 octave/minute

5-20 Hz @ 0.01 g

2

/Hz

20-200 Hz @ -3.0 dB/octave
Random 5-20 Hz @ 1 m

2

/Sec

3

Random 20-200 Hz @ -3 m/Sec

2

Shock

Half-sine, 11 m/Sec, 30mSec/sec

2

Blade level packaging
Half-sine, 6 mSec at 180 m/Sec

2

Free Fall

1,200 mm/all edges and corners
1.0m (Packaged) per ETSI 300
019-2-2 (Blade level packaging)
100mm (unpackaged) per GR-63-
CORE

This manual is related to the following products: