1 cr/csr settings, 2 displaying vme settings, 1 cr/csr settings 4.5.1.2 displaying vme settings – Artesyn MVME55006E Single Board Computer Installation and Use (July 2014) User Manual
Page 79: Motload firmware

MOTLoad Firmware
MVME55006E Single Board Computer Installation and Use (6806800A37J)
79
VMEbus A32/D32 addresses from 0x00000000 to (local DRAM size) address the
local memory of the MVME5500.
The following sections provide additional information pertaining to the VME firmware settings
of the MVME5500. A few VME settings are controlled by hardware jumpers while the majority
of the VME settings are managed by the firmware command utility vmeCfg.
4.5.1.1
CR/CSR Settings
The firmware supports both Auto Slot ID and Geographical Addressing for assigning the
CR/CSR base address dependent on a hardware jumper setting. See the VME64 Specification
and the VME64 Extensions for details. As a result, a 512K byte CR/CSR area can be accessed
from the VMEbus using the CR/CSR AM code.
4.5.1.2
Displaying VME Settings
To display the changeable VME setting, type the following at the firmware prompt:
vmeCfg -s -m
Displays Master Enable state
vmeCfg -s -i(0 - 7)
Displays selected Inbound Window state
vmeCfg -s -o(0 - 7)
Displays selected Outbound Window state
vmeCfg -s -r184
Displays PCI Miscellaneous Register state
vmeCfg -s -r188
Displays Special PCI Target Image Register state
vmeCfg -s -r400
Displays Master Control Register state
vmeCfg -s -r404
Displays Miscellaneous Control Register state
vmeCfg -s -r40C
Displays User AM Codes Register state
vmeCfg -s -rF70
Displays VMEbus Register Access Image Control Register state