Driverack, Appendix a, A.2 power up quick key options a.1 factory reset – dbx Pro 260 User Manual
Page 74
®
DriveRack™ User Manual
66
Appendix A
DriveRack
™
In the event that a reset is required, the DriveRack™ 260 offers you the option of performing a “Soft” or “Hard” reset.
The Soft Reset resets all operating parameters except user programs. The Hard Reset Procedure will reset all program-
mable information back to the factory defaults.
All Power-Up Functions require a button(s) to be pressed and held as the unit power is turned on.
DriveRack 260 Power-Up Button Functions
Factory (“Hard”) Reset.
Press and hold the
“! HARD RESET?”
“Yes
“No
• Pressing the
copies of the Factory Programs, all Utility settings will be defaulted, and all Security settings
will be defaulted).
• Pressing the
normally.
System (“SOFT”) Reset
• Press and hold the
“! SOFT RESET?”
“Yes
“No
• Pressing the
• Pressing the
reset normally.
The DriveRack™ 260 offer several “Quick Key” options for initial power up and are as follow:
Change Initial Program Number
• To change the initial power program number, Press and hold the
power-up until the following message appears:
Use Wheel to”Change Restart”Program Number”
• Turning the wheel will select the program you wish to load at initial reset.
• Press the
continue.
System Lock Out
• Press and hold
System Unlocked All user input will be accepted
or
System Locked No user input will be accepted
• Rotating the wheel to select either Lock, Unlock or Filter Unlocked the system.
• Pressing
• If you wish to leave the system locked with the exception of being able to clear the feedback filters, follow the same
procedure on power up and then rotate the wheel to select the feedback filter unlock feature.
• Pressing any other button will abort the System Lockout sequence and the unit will reset normally.
A.2 Power Up Quick Key Options
A.1 Factory Reset