PT-90 Mobile Computer SDK Programming Manual 165
TagResetToReady
Set select or ouiet tag to ready state.
int TagResetToReady
{
char
lpFlag[]
,
char
lpAddressUID[]
,
}
Parameters
lpFlag
[in] Set request flag, please refer to table belowand
. This parameter displayed in base
hexadecimal notation.
Bit 8
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
0
0
Address_flag
Select_flag
0
0
0
0
lpAddressUID
[in] The unique identifier of ISO 15693 tag. This parameter apply determined by the Address_flag, please
refer to ISO 15693 document.
Returned Values
Returning zero if the operation is successful, otherwise, indicates failure.
Example
char cUID[40];
Inventory15693("04", "", cUID);
if(TagResetToReady("20", cUID) != 0)
AfxMessageBox(_T("Set ready state fail"));
Requirements
OS Versions: Windows CE 6.0 or beyond.
Header: RFID.h
Link Library: RFID.lib
Link DLL: RFID.dll
Device: PT90