Industrial 2 of 5 – Argox AS-8020CL User Manual
Page 87

81
Industrial 2 of 5
Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group number selection: Refer to page 57
th
Insertion group number selection of UPCA.
Option Bar Code
Option
Alphanumeric
Entry
Read
Disable
Enable
00
*
01
Max. code length
00-64 00-64
00
*
Min. code length
00-64 00-64
00
*
Program