Calibrate
This function offers two ways to calibrate your touch screen. ‘Standard Calibration’
adjusts most touch screens. ‘Advanced Calibration’ adjusts aging touch screens.
Standard Calibration Click this button and arrows appear pointing to red squares. Use
your finger or stylus to touch the red squares in sequence. After
the fifth red point calibration is complete. To skip, press ‘ESC’.
Advanced Calibration Advanced Calibration uses 4, 9, 16 or 25 points to effectively
calibrate touch panel linearity of aged touch screens. Click this
button and touch the red squares in sequence with a stylus. To
skip, press ESC’.
Command Calibration Command call calibration function. Use command mode call
calibration function, this can uses Standard, 4, 9, 16 or 25 points to
calibrate E.g. Please run ms-dos prompt or command prompt
c:\Program Files\PenMount Universa Driver\Dmcctrl.exe -calibration
0 ( Standard Calibration) Dmcctrl.exe - calibration ($) 0= Standard
Calibration 4=Advanced Calibration 4 9=Advanced Calibration 9
16=Advanced Calibration 16 25=Advanced Calibration 25
Step 1. Please select a device then click “Configure”. You can also double click the
device too.
Step 2.Click “Standard Calibration” to start calibration procedure