beautypg.com

Aplex Technology ARCHMI-707 User Manual

Page 32

background image

30

Step 5: The function switch setting shows up











10. S_422:

(Switch), COM1 setting, it provides selectable RS232 or RS422 or RS485 serial signal output.

Function

S_422

RS232 (Default)

OFF: Pin1, Pin2, Pin3, Pin4

RS422 (option)

ON: Pin1, Pin2, Pin3, Pin4

RS485 (option)

ON: Pin1, Pin2, Pin3, Pin4

11. COM1:

(Type DB9),Rear serial port, standard DB9 Male serial port is provided to make a direct connection to
serial devices. COM1 port is controlled by pins No.1~6 of JP1, select output Signal RI or 5V or 12V, For
details, please refer to description of JP1 and S_232 and S_422 setting.

RS232 (Default):

Pin#

Signal Name

1

DCD#

(Data Carrier Detect)

2

RXD (Received Data)

3

TXD (Transmit Data)

4

DTR (Data Terminal Ready)

5

Ground

6

DSR (Data Set Ready)

7

RTS (Request To Send)

8

CTS (Clear To Send)

9

JP1 select Setting (RI/5V/12V)