Analog Way Smart MatriX LE - SMX100 Programmer's Guide User Manual
Page 39
39
Group
Name
CmdResp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
REFCURRENTREQUEST
Xe Xe
Current Frame Lock source
Rd/Wr 0
15
0
0 = Analog input 1 as reference
1 = Analog input 2 as reference
2 = Analog input 3 as reference
3 = Analog input 4 as reference
4 = Analog input 5 as reference
5 = Analog input 6 as reference
8 = DVI 1 input as reference
9 = DVI 2 input as reference
10 = SDI 1 input as reference
11 = SDI 2 input as reference
14 = Back End 1 as reference
15 = Back End 2 as reference
0 = Main output
1 = Preview output
REFMODE
Xm Xm Follow mode requested by user
Rd/Wr 0
5
0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview output
REFCURRENTMODE
Xc Xc
Current follow mode
Rd/Wr 0
5
0
0 = Internal
1 = Follow x1/2
2 = Follow x1
3 = Follow x2
4 = Follow x3
5 = Asynchronous Follow
0 = Main output
1 = Preview output
REFFREQ
Xt
Xt
Frame rate of the reference signal
Rd
0
655350
Unit = 1/100Hz
0 = Main output
1 = Preview output
REFLOCKSTATUS
Xl
Xl
Framelock locked status
Rd
0
1
0
1 = locked
0 = Main output
1 = Preview output
LAN
LANENABLE
ne ne
LAN enable
Rd/Wr 0
1
0
0 = Enable RS232 ( disable LAN )
1 = Enable LAN ( disable RS232 )
LANRESET
nr
nr
LAN factory parameters reset
Rd/Wr 0
1
0
Auto reset
LANSTORE
ns
ns
LAN parameters update
Rd/Wr 0
1
0
Auto reset
LANIP
nw nw
LAN devices addresses
Rd/Wr 0
255 192
IP : 0 to 255
0 = Device
1 = Remote
2 = Gateway
0 = IP address
high byte
1 = IP address mid
high byte
2 = IP address mid
low high byte
3 = IP address low
byte
LANPORT
np np
LAN port numbers
Rd/Wr 0
6553510500
Local port : 10000 à 10999
Remote port : 0 à 65500
0 = Device
1 = Remote
2 = Gateway
LANNETMASK
nk
nk
LAN netmask
Rd/Wr 0
24
8
Number of 0bits from the right