Analog Way Eikos - EKS500 Programmer's Guide User Manual
Page 14

14
Group
Name
CmdResp Description
Read /
Write
Min
Value
Max
value
Default
value
Values
Index #1
Index #2
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_INVERT
KI
KI
Invert keying area
Rd/Wr 0
1
0
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
IN_KEYING_GRAB_ENABLE
Kg Kg
Enable/disable the keying color
grabber mode
Rd/Wr 0
1
0
0 = Disable the grabber
1 = Enable the grabber
IN_KEYING_GRAB_GET
Kc Kc
Capture the coolor selected by
the grabber and apply the
settings
Rd/Wr 0
1
0
Percent of
OSCREEN_UTIL_H
IN_KEYING_GRAB_H
Kh Kh
Horizontal position of the
grabber
Rd/Wr 0
65535 32768
Precent of
OSCREEN_UTIL_V
IN_KEYING_GRAB_V
Kv Kv
Vertical position of the grabber Rd/Wr 0
65535 32768
Auto reset
INPUT
STATUS
SIG_HPOL
sh
sh
Input H sync polarity
Rd
0
1
0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14
SIG_VPOL
sv
sv
Input V sync polarity
Rd
0
1
0
0 = Negative Synchro
1 = Positive Synchro
0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5