2.10 Basic Initial Functional Test

CAUTION:

Work carefully when performing these tests; hazardous voltages

are present on the input and output during this test.

Refer to Figure 2-16 for the required functional test set up. Proceed as follows to perform a basic
function check of the power system:

1. Verify the correct AC line input rating on the nameplate of the MX unit(s) and make sure the

correct three-phase line voltage is wired to the input of the MX before applying input power.

2. Connect a suitable resistive or other type load to the output of the MX. The load resistance

value will depend on the voltage range you plan to check. Make sure the power resistor has
sufficient power dissipation capability - up to 15 KW for full load test on one phase of MX45-3
- and that the load used does not exceed the maximum power rating of the MX45. For three
phase configurations, this test can be performed on one phase at a time if needed.

3. Connect an oscilloscope and DMM / voltmeter to the AC source output. Set both for AC

mode.

4. If the correct voltage is present, turn on the MX unit(s) by closing the On/Off circuit breaker

on the front panel. For multi-cabinet systems, turn on the auxiliary unit first and wait for them
to cycle on, then turn on the master unit.

5. If the MX has more than one available output voltage range, go to the PROGRAM 1 screen

and select the desired voltage range. The output mode can be set from the PROGRAM 2
screen (use the MORE soft key or press the PROGR function key again). Select AC mode.

6. Set the output voltage to 0 volt and close the output relay with the OUTPUT ON/OFF button.

There should be little or no output although the DMM may show a noise level, especially if the
DMM is in auto ranging mode.

7. Move the cursor to the VOLTAGE field in the PROGRAM 1 screen and either use the

keyboard to program a small voltage (20 VAC) or slew the voltage up slowly with the knob.
Observe the DMM reading. The reading should track the programmed voltage.

8. Also monitor the scope. The output should be a sinusoidal voltage waveform.

9. If the output tracks, increase the voltage till you reach 80 % of the voltage range or more.

Check the output voltage reading and waveform.

10. Select the MEASUREMENT 1 screen by pressing the MEAS button. The output voltage,

current and power will be displayed. For three phase configurations, use the PHASE button
to select the øABC display mode. This will show the voltage, current and power for all three
phases. If all phases are loaded equally, the same current and power should be visible for all
three unless the voltages are not programmed to the same level. If only one phase is loaded,
current and power will only be shown for the loaded phase.

In the unlikely event the power source does not pass the functional test, refer to the calibration
procedure in the MX Series User manual (P/N 7003-

960) or call California Instrument’s customer

satisfaction department for further assistance.