Sorensen DCS Series 1kW and 1.2kW Supplies

Maintenance and Troubleshooting

M362500-01 Rev H

4-3

Symptom

Check

Further Checks and Corrections

Output voltage
fluctuating or
regulation poor

Is unit at current limit?

See Section 2.5.

Is input voltage within
specified range?

Measure voltage on input terminals.
See Section 1.4.

Are sense lines connected?

See Section 2.6.4.

Is unit under remote analog
control?

See Section 2.11.

Internal circuit?

Call Customer Service.

Output oscillating

Long sense leads?

See Section 2.6.4.

Inductance in load cables with
capacitive load?

See Section 2.6.3.

Internal circuit?

Call Customer Service.

4.4 Calibration

Calibration is performed at the factory during testing. Recalibration should be performed
annually and following major repairs. Calibration should be done with the cover on, through
the access holes in the cover. See Figure 4-1 below. Calibration on both the A1 and A2
assemblies is accomplished using multiturn trimpots. The list below gives the circuit designation
of the trimpot and the parameter affected by that part.

Circuit Designation

Assembly

Parameter Affected

R7

A2

Output Current Monitor Calibration

R46

A2

Output Current Monitor Offset

R47

A2

Current Control Circuit Offset

R48

A2

Output Current Range

R52

A2

Voltage Control Circuit Offset

R53

A2

Output Voltage Range

R18

A1

Front Panel Voltmeter Calibration

R15

A1

Front Panel Ammeter Calibration

Note: Consult the factory for full calibration requirements.