Sorensen DCS Series 1kW and 1.2kW Supplies

Installation and Operation

M362500-01 Rev H

2-23

2.12 Remote Monitoring and Status Indicators

Readback signals for remote monitoring of the output voltage and current are available at
connector J3 on the rear of the unit. A 0-5V (uncalibrated) signal between pins 19 (positive)
and 12 (negative) represents 0-100% of the rated output voltage. A 0-5V (calibrated) signal
between pins 7 (positive) and 12 (negative) represents 0-100% of the rated output current. The
offset and gain of the current readback signal may be adjusted through holes in the cover of the
unit (see Section 4.4 Calibration for location of adjusting holes).

Status indicators for thermal shutdown, OVP operation, remote programming and operating
mode are also available through the J3 connector. The table below lists the various signals, the
J3 connector pins where they are available, the approximate magnitude of the signal (measured
with respect to pin 6 of connector J3) and the source impedance through which the signal is
fed.

Indicator Signal

J3 Connector Pin

Signal Voltage

Source Impedance

Thermal Shutdown

18

+10V

750

OVP Circuit Activated

17

+9V

750

Remote Programming

4

+10V

750

Voltage Mode
Operation

5

+10V

750

Current Mode
Operation

5

-3V

750

Monitor Signal

J3 Connector Pin

Jumper Selection

Output Signal

Range

Source

Impedance

Output Voltage

19 (+)

6 (RTN)

JP1

OUT

IN

0

–5V

0

–10V

100

Output Current

7 (+)

6 (RTN)

JP2

OUT

IN

0

–5V

0

–10V

100