Programming with an external current source -22 – AMETEK DCS-E 1KW Series User Manual
Page 44

Installation and Operation
Sorensen DCS Series 1kW and 1.2kW Supplies
2-22
M362500-01 Rev H
2.11.3 Programming With an External Current Source
The output voltage and current limit can be programmed using an external 0-1mA current
source.
To program the output voltage, set the front panel voltage control to maximum, set switch
SW1-3 open (default factory setting) and remove the jumper between pins 20 and 21 of
connector J3. Connect the external current source between pins 8 (positive) and 12 (return) of
connector J3. Varying the current source from 0-1mA will vary the output voltage from 0-100%
of the rated output.
S
W
1
-1
S
W
1
-2
S
W
1
-3
S
W
1
-4
S
W
1
-5
S
W
1
-6
S
W
1
-7
S
W
1
-8
CLOSED
CONNECTOR J3
0-1mA
1312
25
8
1
14
SWITCH SW1
OPEN
Switch SW1 and Connector J3 Configuration
for 0-1mA Current Programming of the Output Voltage
(J3 sense line, OVP and current control jumpers shown set for local operation)
To program the output current limit, set the current control to maximum, set switches SW1-1
and SW1-2 open (factory setting) and remove the jumper between pins 22 and 23 of connector
J3. Connect the external current source between pins 11 (positive) and 12 (return). Varying
the current source from 0-1mA causes the current limit to vary from 0-100% of rated maximum.
S
W
1
-1
S
W
1
-2
S
W
1
-3
S
W
1
-4
S
W
1
-5
S
W
1
-6
S
W
1
-7
S
W
1
-8
CLOSED
CONNECTOR J3
0-1mA
1312
25
11
1
14
SWITCH SW1
OPEN
Switch SW1 and Connector J3 Configuration
for 0-1mA Current Programming of the Output Current Limit
(J3 sense line, OVP and voltage control jumpers shown set for local operation)