Electrical specifications for 1.2kw models -4, 2 electrical specifications for 1.2kw models – AMETEK DCS-E 1KW Series User Manual

Page 20

background image

Features and Specifications

Sorensen DCS Series 1kW and 1.2kW Supplies

1-4

M362500-01 Rev H

1.4.2

Electrical Specifications for 1.2kW Models

Specifications are warranted over a temperature range of 0-50°C with default local sensing.
From temperatures of 50-70°C, derate output 2% per °C.

Models

8-140 10-120 20-60 33-36 40-30 50-24 60-20 80-15 100-12 150-8 300-4 600-2

Output Ratings:
Output Voltage
Output Current
Output Power


0-8V
0-140A
1200W


0-10V
0-120A
1200W


0-20V
0-60A
1200W


0-33V
0-36A
1200W


0-40V
0-30A
1200W


0-50V
0-24A
1200W


0-60V
0-20A
1200W


0-80V
0-15A
1200W


0-100V
0-12A
1200W


0-150V
0-8A
1200W


0-300V
0-4A
1200W


0-600V
0-2A
1020W

Line Regulation:

7

Voltage
Current


8 mV
140 mA


10 mV
120 mA


20 mV
60 mA


33 mV
36 mA


40 mV
30 mA


50 mV
24 mA


60 mV
20 mA


80 mV
15 mA

100

mV

12 mA


150 mV
8 mA


300 mV
4 mA


600 mV
2 mA

Load Regulation:

8

Voltage
Current


8 mV
140 mA


10 mV
120 mA


20 mV
60 mA


33 mV
36 mA


40 mV
30 mA


50 mV
24 mA


60 mV
20 mA


80 mV
15 mA

100

mV

12 mA


150 mV
8 mA


300 mV
4 mA


600 mV
2 mA

Meter Accuracy:
Voltage
Current


0.09V
1.55A


0.11V
1.3A


0.3V
0.7A


0.43V
0.46A


0.5V
0.40A


0.6V
0.34A


0.7V
0.3A


0.9V
0.25A


1.1V
0.13A


1.6V
0.09A


4.0V
0.05A


7.0V
0.021A

OVP Adjustment Range 0.4-8.8V 0.5-11V 1.0-22V 1.65-36.3V 2-44V

2.5-55V 3-66V

4-88V

5-110V 7.5-165V 15-330V 30-660V

Output Noise/Ripple(V)

9

Rms
p-p
(20Hz-20MHz)

5 mV
60 mV

5 mV
60 mV

5 mV
60 mV

5 mV
60 mV

5 mV
60 mV


5 mV
60 mV


5 mV
60 mV


5 mV
60 mV


10 mV
60 mV


15 mV
160 mV


25 mV
200 mV


50 mV
300 mV

Stability:

10

Voltage
Current


4 mV
70 mA


5 mV
60 mA


10 mV
30 mA


16.5 mV
18 mA


20 mV
15 mA


25 mV
12 mV


30 mV
10 mA


40 mV
7.5 mA


50 mV
6 mA


75 mV
4 mA


150 mV
2 mA


300 mV
1 mA

Temperature

Coefficient:

11

Voltage
Current

1.6 mV
42 mA

2 mV
36 mA

4 mV
18 mA

6.6 mV
10.8 mA

8 mV
9 mA

10 mV
7.2 mA

12 mV
6 mA

16 mV
4.5 mA

20 mV
3.6 mA

30 mV
2.4 mA

60 mV
1.2 mA

120 mV
0.6 mA

Maximum Remote
Sense Line Drop

12

Compensation/line

2V

2V

4V

4V

4V

4V

4V

4V

4V

4V

4V

4V

7

For input voltage variation over the AC input voltage range, with constant rated load

8

For 0-100% load variation, with constant nominal line voltage

9

Typical P-P noise and ripple

10

Maximum drift over 8 hours with constant line, load, and temperature, after 20-minute warm-up

11

Change in output per °C change in ambient temperature, with constant line and load

12

Line drop subtracts from the maximum available output voltage at full rated power

AC Input: 200-250 Vac at 10A rms or 100-130 Vac at 20A rms, 47-63 Hz

Maximum Voltage Differential from output to safety ground: 150 Vdc