Sorensen DCS Series 1kW and 1.2kW Supplies

Installation and Operation

M362500-01 Rev H

2-21

S

W

1

-1

S

W

1

-2

S

W

1

-3

S

W

1

-4

S

W

1

-5

S

W

1

-6

S

W

1

-7

S

W

1

-8

CLOSED

CONNECTOR J3

5k OHMS

CCW

1312

25

9

21

1

14

SWITCH SW1

OPEN

Switch SW1

SW1-1 Off (Open)
SW1-2 Off (Open)
SW1-3 Off (Open)

SW1-4 On (Closed)

SW1-5 Off (Open)
SW1-6 Off (Open)
SW1-7 Off (Open)

SW1-8 On (Closed)

Switch SW1 and Connector J3 Configuration

for Resistive Programming of the Output Voltage

(J3 sense line, OVP and current control jumpers shown set for local operation)

To program the output current limit, set switches SW1-1 and SW1-2 open (default factory
setting) and remove the jumpers connecting pins 10 to 11 and 22 to 23 on connector J3.
Connect pins 10 and 22 to the counterclockwise end of the 5k potentiometer and connect the
tap and clockwise end of the potentiometer to pin 12. Adjusting the tapped resistance from
0-5k will vary the current limit from 0-100% of the rated output.

S

W

1

-1

S

W

1

-2

S

W

1

-3

S

W

1

-4

S

W

1

-5

S

W

1

-6

S

W

1

-7

S

W

1

-8

CLOSED

CONNECTOR J3

5k OHMS

CCW

1312

25

10

22

1

14

SWITCH SW1

OPEN

Switch SW1

SW1-1 Off (Open)
SW1-2 Off (Open)
SW1-3 Off (Open)

SW1-4 On (Closed)

SW1-5 Off (Open)
SW1-6 Off (Open)
SW1-7 Off (Open)

SW1-8 On (Closed)

Switch SW1 and Connector J3 Configuration

for Resistive Programming of the Output Current Limit

(J3 sense line, OVP and voltage control jumpers shown set for local operation)

This manual is related to the following products: