2-1

SECTION 2

POWER-ON AND RESET CONDITIONS

The following sections define the factory and reset power-on conditions of the unit.

2.1 Factory Defaults

When the CW-P unit is first powered up, the following factory defaults will be in place:

GPIB Address:

25

RS-232 Baud Rate:

9600

RS-232 Data Bits:

8

RS-232 Stop Bits:

1

RS-232 Parity:

N

2.2 Power-On Conditions

When the CW-P unit is first powered up, the system reads in the configuration that was
last saved to memory position 0. The specific system items in Save and Recall are:

VoltsA, VoltsB, VoltsC (B and C for multi-unit configuration)

Voltage Range, either High or Low

Current Protection Type, either Fold or Shut

Current Shutdown Time

Current LimitA, Current LimitB, Current LimitC (B and C for multi-unit configuration)

Frequency

Phase AngleAB

Phase AngleAC

External Input Assignment, either Analog In or Pulse Out.