beautypg.com

5 status commands -4, 6 system commands -4, 5 status commands – AMETEK CW Series Programming Manual User Manual

Page 13: 6 system commands

background image

SCPI Commands

Elgar CW-P Series

3-4

Programming Manual

3.5 STATUS Commands

:STATus

The status commands tree.

:OPERation?

SCPI commands returns „1‟.

:OPERation

The SCPI Operation sub-tree.

:[EVENt?]

Returns „1‟.

:CONDition?

Returns „1‟.

:ENABle

Sets the value in the Operations Enable register.

:ENABle?

Returns the value in the Operations Enable register.

:PRESet

Set the value of the Operations Enable register.

:QUEStionable?

Returns „1‟.

:QUEStionable

:CONDition?

Returns „1‟.

[:EVENt?]

Returns „1‟.

:ENABle

Set the value of the Operations Enable register.

:ENABle?

Returns the value of the Operations Enable register.

3.6 SYSTEM Commands

:SYSTem

The system command tree.

:KLOCK?

Returns „1‟ if the front panel programmable
keys are locked out.

:KLOCK

„1‟ locks the front panel programmable keys.

:CHECKSUM?

Returns the results of the checksum test.
1 = the checksum passed, 0 = failed.

:CHECKSUM

Specify that the CW shall re-check its flash
checksum.

:COMMunicate

The communications sub-tree.

:GPIB

The GPIB communications channel.

[:SELF]

SCPI sub-command.

:ADDRess []

Set the GPIB address to a value of 1..31.

:ADDRess?

Returns the GPIB address presently set.

:AUTORUN

„1‟ (ON) specifies the CW will automatically
close the output relay at power-

up. „0‟ (OFF)

specifies the CW will power up in standby.

:AUTORUN?

Returns the state of the autorun parameter,
either „0‟ or „1.‟

:STORe

Specify that the present system setpoint/
register set shall be saved to EEPROM at the
address. shall be 0..98.