3-5
:STORe?
Return the present EEPROM register
address that was read to set the present
setpoint/register values. CW shall read in
EEPROM address 0 at power-up.
:RECall
Specify that CW shall read in the EEPROM
setpoint/registers from EEPROM location
:ERRor?
Return the last Error logged by the GPIB/
RS-232 command processor. If there are no
errors, CW shall return as SPACE.
:EXTernal
External connectors sub-tree.
:CLOCk?
Return the present state of the Clock/Lock
connector interface circuit.
:CLOCk
„IN‟ sets the Clock/Lock connector interface to
a
n input, „OUT‟ makes the pin an output. See
Operation Manual for the pinout of connectors.
:LOCK?
Returns 1 if the Phase Lock Loop is in the
acquired (locked) state.
:ANAIN
„1‟ (ON) specifies that the CW amplifiers will
slew 0 through programmed value in relation
to a 0-5 volt control signal. See Operation
Manual for connector pinouts.
:ANAIN?
Returns „1‟ if ANAIN is enabled.
:SERIALNO?
Returns the serial number.
:VER[S][ion]?
Return the code version of the FLASH
application presently active in the CW.
3.7 Master/Slave Commands
:SLAVECONFIG
Accepts A0A0,A0A1,A0A2,A0A3,A0A4,A0A5,
A0B0,A0B1,A0B2,A0B3,A0B4,A0B5,A0C0,
A0C1,A0C2,A0C3,A0C4,A0C5.
See Operation Manual for usage of these
master/slave configuration options.
:SLAVECONFIG?
Returns A0A0,A0A1,A0A2,A0A3,A0A4,A0A5,
A0B0,A0B1,A0B2,A0B3,A0B4,A0B5,A0C0,
A0C1,A0C2,A0C3,A0C4,A0C5.
:SLAVEADDR
Accepts 0-5. See Operation Manual for usage.
:SLAVEADDR?
Returns 0-5.
:SLAVECHAN
Accepts A,B,C. See Operation Manual for usage.
:SLAVECHAN?
Returns A-C.