beautypg.com

AMETEK CW Series Programming Manual User Manual

Page 25

background image

Sample Programs

Elgar CW-P Series

C-2

Programming Manual

8.

Turn On RMS loop

SOUR:VOLT:RMSLOOP ON (1)

9.

Turn Off RMS loop

SOUR:VOLT:RMSLOOP OFF (0)

10.

Turn Off RMS loop

SOUR:VOLT:RANGE LO

SOUR:VOLT 120

OUTPUT ON

The CW-P will source 120V to the output
terminals in low range. If you send the command:

If you send the command:

SOUR:VOLT:RANGE HI The output relay will open, the voltage will drop

to zero.

11.

If the CW-P supply is sourcing to the output terminals (output relay closed,
voltage>0), and you send the command:

SYST:RECALL 31

(any number 0..99)

When the recalled parameters are in the same
range that the CW-P is presently operating in,
the output relay will remain closed, and the
voltage, phase, current limit, etc. will go to the
new values.

When the recalled parameters are in the
opposite range (LOW, HIGH) that the CW-P
is presently operating in, the output relay will
remain open, delay one second, and then re-
close. Then CW-P then will go to the new
recalled parameters.