Rs-232 pinout and baudrate settings, Tcp/ip settings used by the hda800(v2), Pin definitions – Zektor Palladia™ 8X8 User Manual
Page 28: Port settings used by the hda800(v2), Rs-232 / tcp/ip port hardware
28
HDA800(V2) Serial Protocol, Version 1.3, 9/12/13
RS-232 / TCP/IP Port Hardware
TCP/IP settings used by the HDA800(V2)
Default IP Address:
DHCP
Port Number:
50005
Duplex:
Full
Speed:
10/100 Mbps
RS-232 Pinout and Baudrate Settings
The RS-232 port on the HDA800(V2) is the same format, and pinout, as a PC modem, and uses the
same type of cable as a standard serial modem would, which is a standard straight through cable. Do
not use a cable that is marked as a “Null Modem” cable.
The HDA800(V2) can also be used with USB to RS-232 conversion cables, these are all typically
straight through cables. (Be sure to install any drivers that come with the USB to RS-232 cable you are
using.)
The RS-232 port is a female type DE-9 connector (sometimes mistakenly referred to as a DB-9 con-
nector) with the following pinout:
Pin definitions
1 - No Connect
6 - No Connect
2 - TX
7 - No Connect
3 - RX
8 - No Connect
4 - No Connect
9 - No Connect
5 - GND
Port settings used by the HDA800(V2)
Baudrate:
19200
Data Bits:
8
Stop Bits:
1
Parity:
NONE
Timing information (unless specified otherwise by a command’s description)
Min character to character time:
0ms
Min line to line time:
0ms
Min time between commands:
0ms
Max time to respond to a request:
100ms