2 customer specification (141 settings) – Digi Counting Version 4.0 DC-190 User Manual
Page 13

18
DC-190 Ultra Count Installation Manual
4.2
Customer Specification (141 Settings)
To configure customer specifications, press and hold the
REZERO
key and enter
141
using the numeric keypad.
SPC00
appears in the
WEIGHT
display and configuration of four bits (for SPEC 0) appears in
QUANTITY
display.
Follow the procedure described in Section 4.1 on page 17 to update the SPEC settings for the 141 access code.
SPEC
Default
Bit 3
Bit 2
Bit 1
Bit 0
0
0000
Transfer Tare Weight
0: No (hold tare)
1: Yes (transfer tare)
Tare Accumulation
0:
No (overwrite tare)
1:
Yes (add to existing
tare)
Terminator (RS-232 only)
0: Carriage return
1: Carriage return +
linefeed
Piece Weight Selection
0: Unit wt per 1000
1: Average piece wt
(APW)
1
0000
Power Auto Off Function: Function used to preserve and extend battery life. All four bits are used to
specify the number of minutes (binary) before the scale enters autopower off mode.Examples below show
the binary code, time delay, and description. Settings can range from 0–15 minutes in 1-minute
increments.
Binary Code
8421 Time (min) Description
0000
0
Autopower off is disabled.
0111
7
If net weight is zero and no motion for 7 minutes, scale goes into autopower off mode.
1111
15
If net weight is zero and no motion for 15 minutes, scale goes into autopower off mode.
NOTE: Powering down means that accumulated value is lost and not retained upon power up. However,
all total inventory values stored with item codes are retained.
2
1000
Scale Specification
00: Gram (no units switching)
01: Kg
10: Lb
11: Not used
NOTE: Values 01 and 10 allow Lb/Kg units
switching if SPEC 2, bit 1 is set 0.
Kg/Lb Lamp Enable
0: Yes
1: No
Inventory Display by Net/
Gross Key
0: No (Net/Gross toggle)
1: Yes (INVENT key
shows inventory quantity)
3
0000
RS-232 Port Commands (D-sub)
00:
Standard RS-232 (PC, force balance)
01:
TM-U295 ticket printer
10:
TM-U200 (with or without cutter)
11:
TM-U200 (with feed for tear-off)
Print Commands (8-pin DIN)
00:
BCP-30 (barcode printer, force balance)
01:
TM-U295 ticket printer
10:
TM-U200 (with or without cutter)
11:
TM-U200 (with feed for tear-off)
4
1001
Set New Item Code
During Normal Mode
0:
Yes
1:
No
Insufficient Sample Level
00:
0.1%
01:
0.2%
10:
0.0%
Negative Counting
0: No
1: Yes
5
1011
Sampling Time for Unit
Weight Calculations
0:
10 times
1:
5 times
Unit Weight
Auto-Recomputing
0:
Press PIECES key
after adding number of
pieces
1:
Scale automatically
recomputes after
adding number of
pieces without pressing
PIECES key
Date Order
00:
Year, Month, Day
01:
Day, Month, Year
11:
Month, Day, Year
6
1001
Display Accuracy of
Unit Weight
0:
No
1:
Yes
Clear Key Operation
0:
Clear all data
1:
Clear last character
RS-232 Continue
Sending Rate to PC
0: High
1: Low
Auto Shift to Next
Character After Two Digits
of Teraoka Code Entry
0: No (requires
+
key)
1: Yes
Table 4-1. DC-190 141 Settings