LEAVE ADEQUATE CLEARANCE BEHIND ENCLOSURE FOR WIRING AND VENTILATION COWLS
Tempest Lighting recommends the use of stainless steel mounting hardware.
The Twister enclosure is provided with two mounting brackets for wall, floor or ceiling mounting.
Wall anchors and screws are not provided and must comply with local building codes and safety
regulations.
Twister may also be installed using Tempest Pipe Clamps or conventional hanging clamps fitted to
the two holes in the base for either ½” US or M12 hardware.
Dimensions for Twister mounting Brackets
A
B
C
Twister 1800
8.25”/210
4.75”/121
3.0”/76
Twister 1850
15.5”/394
4.75”/121
6.0”/152
Twister 1900
15.5”/394
4.75”/121
6.0”/152
It is the responsibility of the installer to ensure that all mounting points are secure and conform to local
safety regulations. Tempest Lighting Inc. accepts no responsibility for damage or injury arising from
inappropriate or unsafe installation.
Mount Twister to a pipe or truss using two Tempest
stainless steel U-bolt kits:
4900.MCT Stainless Steel Unistrut channel nut, bolt
and pipe clamp, for pipes 1.5” (38mm) to 2” (50mm)
OD. Two required per enclosure.
4925.MCT Stainless Steel Unistrut channel nut, bolt
and pipe clamp, for pipes 2” (50mm) to 2.5” (64mm)
OD. Two required per enclosure.
A
B
C
Using the mounting
brackets provided,
secure with two screws
or bolts each to a solid
surface or structure.
Max screw size
3/8”/M10.