Tempest Twister User Manual
Page 11

Twister Enclosure User Manual
page 11
3.4 Connect AC Wiring to MiniDEC Controller
Single Feed Operation
Split Feed Operation
NEUTRAL
Single Feed Wiring
Feed the controller with a single maintained supply. The enclosure should be powered 24/7. The light must be
switched off when needed using the lighting control system.
Twister ships configured for single feed wiring operation.
Dual Feed Wiring
You may switch off the supply to the light without interfering with the cooling fan operation. Connect feeder wires
as shown, AND CUT THE COPPER LINK ON THE MiniDEC BOARD IN TWO PLACES, AS SHOWN. Fan circuit should
be maintained 24/7.
3.5 Replace MiniDEC Cover
NEUTRAL
GROUND
LIVE (Fan)
LIVE (Light and Fan)
LIVE (Light)
CUT LINK 2
PLACES FOR
SPLIT FEED
OPERATION
NEUTRAL
GROUND