MiniDEC Operation

The MiniDEC controller monitors current going to the light fixture inside the Twister enclosure, and also heat inside

the enclosure. When it detects that the light is on and/or the internal temperature is getting warm, MiniDEC runs

the enclosure fan. For best results, enclosures must be connected to live power at all times.

MiniDEC Operation is completely automatic.

Summary:

MiniDEC detects current to light >1.5amps

Fan on

MiniDEC detects current to light drop below 1amp

5-minute fan cool-down, then fan off

MiniDEC detects temperature 25-35°C (77-95°F)

Pulse fan to change air every minute

MiniDEC detects temperature >35°C (95°F)

Switch Fan on

MiniDEC LED Indicator

For information and Faultfinding there is an LED indicator on the MiniDEC control board. Function as follows:

LED OFF: MiniDEC is not powered, or power supply has failed.

LED ON: MiniDEC is functioning normally and luminaire power is < 1amp

LED blinking slowly: Luminaire Power > 1 amp, fan on

LED blinking rapidly: Luminaire power has dropped below 1amp. Fan is running for five minutes

for five-minute cool-down