LIZA Enclosure User Manual

page 10

3.2 Remove the Fan Control Cover, and pull AC and Signal control wires through conduit entries, as

shown here.

Power Connections – Single or Split Feed

Single Feed: Enclosure and projector are on the same power circuit. The enclosure will move air in the

event that the enclosure gets warm when the projector is off (recommended). The circuit must be

fused to protect the projector load plus 40W.

Split Feed: Enclosure and projector are on separate power circuits. It is the user’s responsibility to

ensure that the enclosure power is on when the projector is in use. In Split feed operation the LINE

circuit will pull 40W maximum and the SPLIT circuit must be protected to suit the projector load.

Replace the Controller Cover.

LIZA Fan Control
Board

IMPORTANT:

Split Feed – you MUST cut
this link at both ends

Signal Conduit
Entry

Power Conduit

Entry

Duplex IEC C13
Outlet

Line: 90-265VAC

Split Feed (Projector Power) 90-265VAC*

Neutral

Protective Ground/Earth

* Split feed is NOT CONNECTED for

Single Feed operation