Dean & Deluca SCFHDC User Manual
Page 28

HIGH EFFICIENCY DECATHLON SERIES GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-23
1.7.7 Replacing the Frypot
(cont.)
 
12. Remove screws securing flue to frypot (access 
from above; a nut-driver with an extension or 
long screwdriver is required). Retrieve any 
screws dropped into the flue during removal of 
the flue cap and frypot bracket. 
 
 
 
 
 
 
 
 
 
 
 
13. Remove the clevis clip and oil return handle 
rod from the oil return valve at the rear of the 
fryer. Slip Section A of the clevis clip off of 
the oil return handle by pulling up on the rings. 
Slide the oil return handle out of the bracket 
and Section B of the clevis clip. Repeat for the 
drain flush handle (if applicable). 
 
 
 
 
 
 
 
 
 
 
14. Loosen the two screws on the front of the oil 
return handle bracket at the front of the fryer. 
Remove the bracket and handle and set aside 
for reassembly. Repeat for the drain flush 
handle (if applicable). 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Oil-return handle bracket and screws.
 
 
 
 
 
Disconnect oil-return handle from clevis clip 
and valve. 
Removing bolts (arrows) securing flue to 
frypot. 