Appendix C: Watchdog Timer Setting

a

PPendIx

C: w

atChdoG

t

Imer

s

ettInG

ITE8786 WatchDog Programming Guide

#define Superio_Port

0x2E

#define Superio_LDN

0x07

;*Enter the MB PnP mode with 0x87, 0x01, 0x55, 0x55

outportb(Superio_Port, 0x87);

outportb(Superio_Port, 0x01);

outportb(Superio_Port, 0x55);

outportb(Superio_Port, 0x55);

;*Set LDN=0x07 point to the WDT function

outportb(Superio_Port, Superio_LDN);

outportb(Superio_Port+1, 0x07);

;*Setup configuration register 0x72, if set 90h is second, set 10h is minute(WDT output through PWRGD)

outportb(Superio_Port, 0x72);

outportb(Superio_Port+1, 0x90);

;*Setup WDT time-out value. this demo code is used to program the time-out value with 4 sec.

outportb(Superio_Port, 0x73);

outportb(Superio_Port+1, 0x04);

;*Exit the MB PnP Mode

outportb(Superio_Port, 0x02);

outportb(Superio_Port+1, 0x02);