If you forget the IP address or password used for the unit, you can reset the
unit to the default address and/or password by:
Removing power from the unit, inserting a paper clip or similar item into the
reset switch, and keeping it depressed after you re-apply power as follows:
When the reset button is held down while applying power, the 639 will
go into reset process. The red LED is on. If the reset button is down
for 2-7 seconds, the relay will click once and the green LED blinks. If
the Reset button is released at this time, it will reset password to
639set.
If the reset button is down for 8-29 seconds, the relay will click once
and the green LED blinks. If the Reset button is released at this time, it
will reset password and the IP to 192.168.0.2.
If the reset button is down for 30 seconds or more, the relay will click
twice and the green LED blinks. The 639 will go to normal operation
and No Reset will happen. The Reset button is ignored in this case.
Refer to the previous page to utilize ‘NetBurner IPSetup’ to continue setting the
IP information.
If you are connected to the unit through a network, you must use the
‘NetBurner IPSetup’ program supplied with your unit on the included CD.
This program is also available on the ‘NetBurner’ web page.